GTTC-WEB-VP02 Report

OS : Microsoft Windows Server 2019 Standard | SytemUptime : 75 Days, 13 Hours, 03 Minutes, 25 Seconds

CPU Usage


CPU Total
1.28
CPU Used
2.39
CPU Free
-1.11
Concurrent User

GTTC-WEB-VP02 Chart


GTTC-WEB-VP02 CPU-Chart

RAM Usage


Total RAM (GB)
16
Used RAM
8.06
Free RAM (GB)
7.94
Percent free RAM
49.64

GTTC-WEB-VP02 Chart


GTTC-WEB-VP02 Chart

Disk Info (> 30%)


NameSize (GB)FreeSpace (GB)PercentFree
C:99.4072.3372.76
E:99.9892.0992.11

Disk Info Critical (< 30%)


System Processes

Top 10 Highest Memory Usage


The following 10 processes are those consuming the highest amount of Working Set (WS) Memory (bytes) on GTTC-WEB-VP02

ProcessNameIdWS
w3wp1632957779968
SearchUI8296296275968
mstsc1332289091584
dsa3996282951680
powershell_ise11924281481216
explorer10044270118912
explorer12388264130560
SearchUI10468254328832
NWEAgent3608228347904
explorer11360198025216

System Services - Automatic Startup but not Running


The following services are those which are set to Automatic startup type, yet are currently not running on GTTC-WEB-VP02

StatusNameStartMode
StoppedgupdateAuto
StoppedPerfAlarmServiceAuto
StoppedRemoteRegistryAuto
StoppedRTMAServiceAuto
StoppedsppsvcAuto
StoppedwuauservAuto

IIS Work Processor


System/Application Logs

Events Report


The last 3 System/Application Log Events that were Warnings or Error on GTTC-WEB-VP02

MessageTimeGeneratedSourceEntryType
The description for Event ID '10028' in Source 'DCOM' cannot be found. The local computer may not have the necessary registry information or message DLL files to display the message, or you may not have permission to access them. The following information is part of the event:'GTTC-DB-VP02', ' 2e94', 'C:\Windows\system32\WindowsPowerShell\v1.0\PowerShell_ISE.exe', '{8BC3F05E-D86B-11D0-A075-00C04FB68820}'06-04-2023 10:37:58DCOMError
The description for Event ID '10028' in Source 'DCOM' cannot be found. The local computer may not have the necessary registry information or message DLL files to display the message, or you may not have permission to access them. The following information is part of the event:'GTTC-DB-VP02', ' 2e94', 'C:\Windows\system32\WindowsPowerShell\v1.0\PowerShell_ISE.exe', '{8BC3F05E-D86B-11D0-A075-00C04FB68820}'06-04-2023 10:37:37DCOMError
The description for Event ID '10028' in Source 'DCOM' cannot be found. The local computer may not have the necessary registry information or message DLL files to display the message, or you may not have permission to access them. The following information is part of the event:'GTTC-DB-VP02', ' 2e94', 'C:\Windows\system32\WindowsPowerShell\v1.0\PowerShell_ISE.exe', '{8BC3F05E-D86B-11D0-A075-00C04FB68820}'06-04-2023 10:37:16DCOMError

Application log


The following is a list of the last 3 Application log events that had an Event Type of either Warning or GTTC-WEB-VP02

MessageTimeGeneratedSourceEntryType
The user 'Samsung ML-1640 Series' preference item in the 'USB Restrict Policy {FF14306C-05D1-43B3-BBCA-428E288E7F27}' Group Policy Object did not apply because it failed with error code '0x800706ba The RPC server is unavailable.' This error was suppressed.10-04-2023 14:21:00Group Policy PrintersWarning
The user 'Samsung ML-1640 Series' preference item in the 'USB Restrict Policy {FF14306C-05D1-43B3-BBCA-428E288E7F27}' Group Policy Object did not apply because it failed with error code '0x800706ba The RPC server is unavailable.' This error was suppressed.10-04-2023 14:15:50Group Policy PrintersWarning
The user 'Samsung ML-1640 Series' preference item in the 'USB Restrict Policy {FF14306C-05D1-43B3-BBCA-428E288E7F27}' Group Policy Object did not apply because it failed with error code '0x800706ba The RPC server is unavailable.' This error was suppressed.10-04-2023 13:36:51Group Policy PrintersWarning

GTTC-WEB-VP03 Report

OS : Microsoft Windows Server 2019 Standard | SytemUptime : 69 Days, 23 Hours, 53 Minutes, 17 Seconds

CPU Usage


CPU Total
1.28
CPU Used
2.39
CPU Free
-1.11
Concurrent User

GTTC-WEB-VP03 Chart


GTTC-WEB-VP03 CPU-Chart

RAM Usage


Total RAM (GB)
16
Used RAM
5.93
Free RAM (GB)
10.07
Percent free RAM
62.94

GTTC-WEB-VP03 Chart


GTTC-WEB-VP03 Chart

Disk Info (> 30%)


NameSize (GB)FreeSpace (GB)PercentFree
C:99.4073.5974.04
E:99.9893.8893.90

Disk Info Critical (< 30%)


System Processes

Top 10 Highest Memory Usage


The following 10 processes are those consuming the highest amount of Working Set (WS) Memory (bytes) on GTTC-WEB-VP03

ProcessNameIdWS
firefox6500495853568
dsa4108277262336
SearchUI11120274833408
SearchUI3236262356992
explorer5984251887616
explorer7940194019328
NWEAgent3496152797184
ShellExperienceHost11012140259328
Registry104134758400
WinSCP13028133046272

System Services - Automatic Startup but not Running


The following services are those which are set to Automatic startup type, yet are currently not running on GTTC-WEB-VP03

StatusNameStartMode
StoppedPerfAlarmServiceAuto
StoppedRTMAServiceAuto
StoppedsppsvcAuto
StoppedwuauservAuto

IIS Work Processor


System/Application Logs

Events Report


The last 3 System/Application Log Events that were Warnings or Error on GTTC-WEB-VP03

MessageTimeGeneratedSourceEntryType
The processing of Group Policy failed. Windows attempted to read the file \\INFRA.KARNATAKA.GOV.IN\sysvol\INFRA.KARNATAKA.GOV.IN\Policies\{31B2F340-016D-11D2-945F-00C04FB984F9}\gpt.ini from a domain controller and was not successful. Group Policy settings may not be applied until this event is resolved. This issue may be transient and could be caused by one or more of the following: a) Name Resolution/Network Connectivity to the current domain controller. b) File Replication Service Latency (a file created on another domain controller has not replicated to the current domain controller). c) The Distributed File System (DFS) client has been disabled.10-04-2023 14:40:03Microsoft-Windows-GroupPolicyError
The Security System has detected a downgrade attempt when contacting the 3-part SPN cifs/INFRA-ADS-VP01.INFRA.KARNATAKA.GOV.IN/INFRA.KARNATAKA.GOV.IN@INFRA.KARNATAKA.GOV.IN with error code "The attempted logon is invalid. This is either due to a bad username or authentication information. (0xc000006d)". Authentication was denied.10-04-2023 14:40:03LsaSrvWarning
The Security System has detected a downgrade attempt when contacting the 3-part SPN LDAP/INFRA-ADS-VP01.INFRA.KARNATAKA.GOV.IN/INFRA.KARNATAKA.GOV.IN@INFRA.KARNATAKA.GOV.IN with error code "The attempted logon is invalid. This is either due to a bad username or authentication information. (0xc000006d)". Authentication was denied.10-04-2023 14:40:02LsaSrvWarning

Application log


The following is a list of the last 3 Application log events that had an Event Type of either Warning or GTTC-WEB-VP03

MessageTimeGeneratedSourceEntryType
The user 'Samsung ML-1640 Series' preference item in the 'USB Restrict Policy {FF14306C-05D1-43B3-BBCA-428E288E7F27}' Group Policy Object did not apply because it failed with error code '0x800706ba The RPC server is unavailable.' This error was suppressed.10-04-2023 14:33:51Group Policy PrintersWarning
The user 'Samsung ML-1640 Series' preference item in the 'USB Restrict Policy {FF14306C-05D1-43B3-BBCA-428E288E7F27}' Group Policy Object did not apply because it failed with error code '0x800706ba The RPC server is unavailable.' This error was suppressed.10-04-2023 12:59:50Group Policy PrintersWarning
The user 'Samsung ML-1640 Series' preference item in the 'USB Restrict Policy {FF14306C-05D1-43B3-BBCA-428E288E7F27}' Group Policy Object did not apply because it failed with error code '0x800706ba The RPC server is unavailable.' This error was suppressed.10-04-2023 11:09:49Group Policy PrintersWarning

GTTC-WEB-VP04 Report

OS : Microsoft Windows Server 2019 Standard | SytemUptime : 75 Days, 14 Hours, 06 Minutes, 54 Seconds

CPU Usage


CPU Total
1.28
CPU Used
2.39
CPU Free
-1.11
Concurrent User

GTTC-WEB-VP04 Chart


GTTC-WEB-VP04 CPU-Chart

RAM Usage


Total RAM (GB)
16
Used RAM
5.31
Free RAM (GB)
10.69
Percent free RAM
66.83

GTTC-WEB-VP04 Chart


GTTC-WEB-VP04 Chart

Disk Info (> 30%)


NameSize (GB)FreeSpace (GB)PercentFree
C:99.4073.0173.46
E:99.9895.4395.45

Disk Info Critical (< 30%)


System Processes

Top 10 Highest Memory Usage


The following 10 processes are those consuming the highest amount of Working Set (WS) Memory (bytes) on GTTC-WEB-VP04

ProcessNameIdWS
dsa532286334976
SearchUI7660273248256
explorer5592263479296
explorer8940215232512
SearchUI1168166256640
NWEAgent3672154849280
ShellExperienceHost7532136228864
Registry104134025216
InetMgr10264133636096
WinSCP8028133079040

System Services - Automatic Startup but not Running


The following services are those which are set to Automatic startup type, yet are currently not running on GTTC-WEB-VP04

StatusNameStartMode
StoppedNetTcpActivatorAuto
StoppedPerfAlarmServiceAuto
StoppedRTMAServiceAuto
StoppedsppsvcAuto
StoppedwuauservAuto

IIS Work Processor


System/Application Logs

Events Report


The last 3 System/Application Log Events that were Warnings or Error on GTTC-WEB-VP04

MessageTimeGeneratedSourceEntryType
The ScRegSetValueExW call failed for Start with the following error: %%504-04-2023 13:02:48Service Control ManagerError
The ScRegSetValueExW call failed for Start with the following error: %%504-04-2023 13:02:47Service Control ManagerError
The ScRegSetValueExW call failed for Start with the following error: %%528-03-2023 13:05:44Service Control ManagerError

Application log


The following is a list of the last 3 Application log events that had an Event Type of either Warning or GTTC-WEB-VP04

MessageTimeGeneratedSourceEntryType
The user 'Samsung ML-1640 Series' preference item in the 'USB Restrict Policy {FF14306C-05D1-43B3-BBCA-428E288E7F27}' Group Policy Object did not apply because it failed with error code '0x800706ba The RPC server is unavailable.' This error was suppressed.10-04-2023 13:32:19Group Policy PrintersWarning
The user 'Samsung ML-1640 Series' preference item in the 'USB Restrict Policy {FF14306C-05D1-43B3-BBCA-428E288E7F27}' Group Policy Object did not apply because it failed with error code '0x800706ba The RPC server is unavailable.' This error was suppressed.10-04-2023 11:58:18Group Policy PrintersWarning
The user 'Samsung ML-1640 Series' preference item in the 'USB Restrict Policy {FF14306C-05D1-43B3-BBCA-428E288E7F27}' Group Policy Object did not apply because it failed with error code '0x800706ba The RPC server is unavailable.' This error was suppressed.10-04-2023 10:12:17Group Policy PrintersWarning